YouTube Video - Paragon HVAC - HMI User Settings

YouTube Video - Paragon HVAC - HMI User Settings

Video Transcript
0:00
in this video we'll review the user
0:02
settings menu user settings can be
0:05
accessed by pressing the top two buttons
0:06
of the HMI
0:08
simultaneously once in user settings
0:10
you'll see temp set points active faults
0:12
fault history and depending on
0:14
configuration scheduling fan speed and
0:17
outdoor air setting it is important to
0:19
note that adjusting scheduling fan speed
0:21
and outdoor air setting can alter unit
0:23
activation capacity and performance
0:26
these should only be adjusted by a
0:27
qualified technician with permission
0:29
from tech support to prevent unintended
0:31
operation to change space temperature
0:33
select temp set points and space set
0:36
points to display the current Heating
0:37
and Cooling set points use the up or
0:40
down buttons to highlight either set
0:41
point and press enter to edit that value
0:44
now that the current highlighted value
0:45
is selected you can use the up or down
0:47
buttons to modify the set point once the
0:50
desired changes have been made you
0:52
should press the enter again which will
0:53
then highlight the entire line
0:55
signifying the change has been stored
0:57
while increasing a heating set point
0:59
don't be alarmed if the cooling set
1:01
point changes as well the same is true
1:03
for decreasing a cooling set point our
1:05
unit will maintain a gap or deadband
1:07
between the two climate control set
1:09
points to keep the unit from cycling
1:10
back and forth frequently between
1:12
heating and cooling it is advised that
1:14
intake set points discharge limits and
1:17
humidity control are not modified as
1:19
this could affect unit activation cause
1:21
unintended discharge temperatures or
1:23
result in poor space humidity any
1:26
changes to these set points should be
1:27
approved by Tech Support to ensure theit
1:29
unit meets the sequence of operation and
1:32
ideal building conditions are
1:34
maintained also in user settings are
1:36
active faults and fault history if any
1:39
faults are present they will be
1:40
displayed in active faults if you have a
1:43
current active fault please reach out to
1:44
captiv a so we can help get it resolved
1:46
promptly fault history will store a log
1:49
of all past faults with a date and time
1:51
stamp per fault don't be alarmed if
1:53
there are faults present as our units
1:55
are tested extensively in our
1:56
manufacturing facilities and during the
1:58
system design verification process
2:00
default history can be cleared in our
2:02
service menu which will be covered in a
2:04
later video the units occupied and
2:06
unoccupied operating set points can also
2:08
be modified in the scheduling section in
2:10
the user settings simply enter
2:12
scheduling then scheduling times to view
2:15
the current start and end for a time of
2:17
occupancy up to three shifts a b or c
2:20
can be configured per day to apply
2:22
varying set points as different heat
2:23
loads or heat demand is necessary for a
2:26
variance in application once you
2:28
configure your desired schedule can be
2:30
applied to the remaining days of
2:31
occupany using the copy schedule
2:33
function here you can copy a schedule
2:36
from one day to the next or from one day
2:38
to all weekdays or all days as always
2:40
it's important to remember that your
2:42
unit schedule was configured from the
2:43
factory for your application any change
2:46
to the schedule should be approved by
2:47
text support prior to being made